Main Standard Drawings Index

Number

Title

Size

  Printing Instructions  
Info Printing Notes 1KB
2-0 General Notes  
2-0-1 Overall General Notes 399KB

2-1

Maintenance Holes

 

2-1-1

Precast Maintenance Hole 1200mm diameter (Deleted)

189 KB

2-1-2

Precast Maintenance Hole 1500mm and 1800mm diameter (Deleted)

188 KB

2-1-3

Precast Maintenance Hole Tees (Deleted)

113 KB

2-1-4

Maintenance Hole Benching Details (Deleted)

104 KB

2-1-5

Maintenance Hole Drop Structure – External Assembly (Deleted)

150 KB

2-1-6

Maintenance Hole Drop Structure – Internal Assembly (Deleted)

125 KB

2-1-7

Maintenance Hole Venting Details (Deleted)

79 KB

2-2

Maintenance Hole Fittings

 

2-2-1

Safety Platform for 1200mm dia. Precast Maintenance Hole (Deleted)

157 KB

2-2-2

Standard Heavy Duty Frame and Cover (Deleted)

95 KB

2-2-3

Water Tight Maintenance Hole Frame and Cover (Deleted)

104 KB

2-2-3A

Detail of Anchoring Method for Water Tight Maintenance Hole – Steel or Aluminum Strap (Deleted)

79 KB

2-2-3B

Detail of Anchoring Method for Water Tight Maintenance Hole – Threaded Rod (Deleted)

76 KB

2-2-4

Maintenance Hole Steps - Aluminum (Deleted)

107 KB

2-3

Bedding and Backfill

 

2-3-1

Bedding Details for Sanitary Sewer (New)

134 KB

2-4

Service Connections

 

2-4-1

Service Connections For Rigid Pipe

175 KB

2-4-1 Service Connections For Rigid Pipe Low to Medium Density (Updated) Pending Approval  

2-4-2

Service Connections For Flexible Pipe

175 KB

2-4-2 Service Connections For Flexible Pipe Low to Medium Density (Updated) Pending Approval  
2-4-3 Service Connections For Flexible or Rigid Pipe Industrial, Commercial or Institutional (New) Pending Approval  

2-4-4

Service Connection Extensions (New Development) (Updated)

145 KB

2-4-5

Grinder Pump to Low Pressure (Updated)

224 KB

2-4-6

Grinder Pump to Low Pressure - The Road Allowance (Updated)

191 KB

2-4-7

Cleanout-Grinder Pump to Gravity Lateral (Updated)

232KB

2-5 New Construction/ Maintenance Holes (Non Pressure Tested) (New)  
2-5-1 General Notes for Precast Maintenance Holes 510 KB
2-5-2 Typical Precast Circular Maintenance Hole Details (1200mm-3000mm) 398 KB
2-5-3 Typical 1200mm Diameter Precast Circular Maintenance Hole Details 435 KB
2-5-4 Typical 1500mm Diameter Precast Circular Maintenance Hole Details 578 KB
2-5-5 Typical 1800mm Diameter Precast Circular Maintenance Hole Details 595 KB
2-5-6 Typical 2400mm Diameter Precast Circular Maintenance Hole Details 630 KB 
2-5-7 Typical HDPE Lined Precast Circular Maintenance Hole Details 216 KB
2-5-9 Typical Precast Rectangular Chamber Details For Large Diameter Sanitary Sewers 475 KB
2-5-10 Typical 1800x2400 Precast Rectangular Chamber Details 650 KB
2-5-11 Typical 2400x3000 Precast Rectangular Chamber Details 684 KB
2-5 12 Typical Safety Landing Platform Configurations For Precast Rectangular Chambers 482 KB
2-5-13 Standard Frame and Cover System Details 192 KB
2-5-14 Integrated Frame and Cover System Details (Suspended for use) 353 KB
2-5-15 Typical Flexible Pipe Wall Connection Details 250 KB
2-5-16 Typical Rigid or Semi-Rigid Pipe Wall Connection Details 279 KB
2-5-17 Typical Ribbed PVC Pipe Wall Connection Details (Deleted) 707 KB
2-5-20 Maintenance Hole Benching Details 177 KB
2-5-21 Maximum Pipe Sizes for Precast Maintenance Holes 439 KB
2-5-22 Maintenance Hole Venting Details 368 KB
2-5-23 Typical Frost Strap Details 193 KB
2-5-24 Sanitary Chamber Marking Post 276 KB
2-5-25 Waterproof Membrane Details 461 KB
2-5-26 Maintenance Holes Drop Structure External Assembly 194 KB
2-2-27 Maintenance Holes Drop Structure Internal Assembly – Existing Maintenance Holes Only 173 KB
2-6 Maintenance Hole Apputenances (New)  
2-6-1 Heavy Duty 660mm Circular Frame and Cover 152 KB
2-6-2 Heavy Duty 745mm Circular Frame and Cover With Inflow Dish Option 228 KB
2-6-3 Standard Heavy Duty Frame and Cover With Inflow Dish Option 199 KB
2-6-4 Heavy Duty Water Tight Frame and Cover 178 KB
2-6-5 Integrated Frame and Cover System With Inflow Dish Option (Suspended for use) 199 KB
2-6-6 High Density Rubber Frame and Cover System With Optional Adjustment Units 266 KB
2-6-7 Detail of Anchoring Method for Water Tight Maintenance Hole With Threaded Rod 214 KB
2-6-8 Detail of Anchoring Method for Water Tight Maintenance Hole With Aluminum, Stainless Steel or Galvanized Strap 205 KB
2-6-9 Typical FRP Ladder Details 289 KB
2-6-10 Typical Aluminum Ladder Details 246 KB
2-6-11 Aluminum Step Details 186 KB
2-6-12 Portable FRP Ladder Details 391 KB
2-6-13 Typical 1200 or 1500 Diameter FRP Safety Landing Details 415 KB
2-6-14 Typical 1200 or 1500 Diameter Aluminum Safety Landing Details 413 KB
2-6-15 Typical Safety Landing Platform Configurations 634 KB
2-7 New PCCP (CCP) Pressure Tested Sanitary Systems (New)  
2-7-1 General Notes for PCCP (CPP) Maintenance Holes 457 KB
2-7-2 Typical 1200mm Diameter CPP Maintenance Hole Details With 600 Diameter Pipe 537 KB
2-7-3 Typical 1500mm Diameter CPP Maintenance Hole Details With 750 Diameter Pipe 720 KB
2-7-4 Typical 1800mm Diameter CPP Maintenance Hole Details With 1050 Diameter Pipe 742 KB
2-7-5 Typical 2400mm Diameter CPP Maintenance Hole Details With 1350 Diameter Pipe 809 KB
2-7-6 Typical 1500mm Diameter CPP Tangent Tee Maintenance Hole Details 529 KB
2-7-7 Typical 1800mm Diameter CPP Tangent Tee Maintenance Hole Details 572 KB
2-7-8 Typical 2400mm Diameter CPP Tangent Tee Maintenance Hole Details 601 KB
2-7-9 CPP to Precast Concrete Riser Transition Detail 158 KB
2-7-10 CPP Anchor Detail for Ladder or Safety Landings 149 KB
2-7-11 Maximum Pipe Sizes for CPP Maintenance Holes 494 KB
2-8 Rehabilitation (New)  
2-8-1 General Notes for Existing Maintenance Holes 447 KB
2-8-2 Typical Existing Precast Maintenance Hole Joint Repair Option – No Excavation 357 KB
2-8-3 Typical Existing Precast Maintenance Hole Liner or Coating Repair Option – No Excavation 348 KB
2-8-4 High Density Rubber Frame and Cover System with Partial Excavation 369 KB
2-8-5 High Density Rubber Frame and Cover System and Composite Grade Adjustment Units With Partial Excavation 384 KB
2-8-6 Standard Frame and Cover System and Precast Grade Adjustment Units with Partial Excavation 448 KB
2-8-7 Integrated Frame and Cover System with Excavation to M.H. Top Riser Section 321 KB
2-8-8 Existing Adjustment Unit Repair with No Excavation 248 KB
2-8-9 Existing Adjustment Unit Repair with No Excavation 208 KB
2-8-10 Typical Existing Maintenance Hole Base Section Internal Repair with No Excavation 225 KB
2-8-11 Cast-In-Place Transition Section from Existing Square Maintenance Hole to Circular Section  with frame and Cover Replacement 536 KB