A-Z List | Accessible Info | Careers | Contact Us

 
--
Images from Peel Region
Public Works on Twitter
Google Translate Feedback
Was this translation useful?
Yes No
Comments on translation:

Thank you for your feedback!
Other Public Works Services
 

Public Works Design, Specification & Procedures Manual

Standard Drawings - Watermain & Appurtenances

Chambers | Chamber Fittings | Valves | Meters
Bedding and Blocking | Fire Protection
Watermain Connections| Servicing for Multiple Buildings
Main Standard Drawings Index

General Summary of Major Drawing Revisions

1-1 Chambers
1-1-0 358KB General Notes and References
1-1-1 401KB Circular Precast Chamber
1-1-2 93KB Small Cast-In-Place Chamber
1-1-3 133KB 750/900 Dia. WM. Valve and Chamber (Cast-In-Place)
1-1-4 92KB Rectangular Precast Chamber
1-1-5 300KB Typical Precast Circular Chamber Details
1-1-6 423KB Typical Precast Rectangular Chamber Details
1-1-7 304KB Typical Precast Circular Chamber Details Over Existing Pipe
1-1-8 139KB Typical Chamber Sump Details

1-2 Chamber Fittings
1-2-1 148KB Safety Platform for 1500mm Diameter Precast Maintenance Hole
1-2-2 49KB Standard Heavy Duty Frame and Cover
1-2-3 61KB Remote Reading Device Installation for Chambers Only
1-2-4 154KB Valve Stem Extension and Bracket
1-2-5 62KB Standard Chamber Steps Aluminum
1-2-6 228KB Typical Valve and Pipe Support Details
1-2-7 95KB Typical Frost Strap Details

1-3 Valves
1-3-1 143KB Detector Check Valve In Chamber
1-3-2 182KB Detector Check, Gate Valve and Pumper in Chamber
1-3-3a 85KB Restraining of 300mm Diameter and Smaller P.V.C. Watermain at In-Line Valve
1-3-4 193KB Typical Concrete Pressure Pipe Wall Piece for Watertight Seal at Precast Chamber Walls
1-3-5 88KB Air Valve and Chamber
1-3-6 64KB Drain Valve and Chamber
1-3-7 87KB Valve Setting for 400mm to 600 mm Pipe
1-3-8 89KB Valve Stem Extension in Valve Box for Watermain 100mm to 300mm Dia. Inclusive
1-3-9 88KB 25mm By-Pass for Detector Check Valve
1-3-10 72KB Pressure Zone Boundary Valve
1-3-11 110KB Valve Box Protection (During Construction)
1-3-12 309KB Air Release Valve and Chamber for Watermain Size Less than 750 Diameter
1-3-13 350KB Air Release Valve and Chamber for Watermain Size 750 Diameter or Greater
1-3-14 324KB Typical Air Release Valve Detail
1-3-15 424KB Typical Drain Chamber Details for Concrete Pressure Pipe 750 Diameter or Greater
1-3-16 264KB Pressure Zone Boundary Valve Chamber
1-3-17 406KB Pressure Reducing Valve in Chamber
1-3-18 472KB Typical Line Valve Chamber for 400mm Concrete Pressure Pipe with Isolation Valve
1-3-19 541KB Typical Line Valve Chamber for 400mm Concrete Pressure Pipe with Isolation Valve and Combination Air Release or Vacuum Valve
1-3-20 559KB Typical Line Valve Chamber for 400mm Concrete Pressure Pipe with Isolation Valve, Double Drain Valve and Combination Air Release or Vacuum Valve
1-3-21 541KB Typical Line Valve Chamber For 600mm Concrete Pressure Pipe With Isolation Valve and 150mm Bypass/Drain Line
1-3-22 609KB Typical Line Valve Chamber For 600mm Concrete Pressure Pipe With Isolation Valve And Combination Air Release Or Vacuum Valve and 150mm Bypass/Drain Line
1-3-23 451KB Typical Line Valve Chamber for 600mm Concrete Pressure Pipe with Isolation Valve, Double Drain Valve and Combination Air Release or Vacuum Valve
1-3-24 467KB Typical Line Valve Chamber for 400mm PVC Pipe with Isolation Valve
1-3-25 546KB Typical Line Valve Chamber for 400mm PVC Pipe with Isolation Valve and Combination Air Release or Vacuum Valve
1-3-26 619KB Typical Line Valve Chamber for 400mm PVC Pipe with Isolation Valve, Double Drain Valve and Combination Air Release or Vacuum Valve
1-3-27 291KB Typical Single Drain Chamber Details for 400 Diameter Concrete Pressure Pipe
1-3-28 291KB Typical Single Drain Chamber Details for 600 Diameter Concrete Pressure Pipe
1-3-29 328KB Typical Single Drain Chamber Details for 400 Diameter PVC Pipe
1-3-30 714KB Typical Line Valve Chamber for 750 Diameter Concrete Pressure Pipe Detail 1 of 2
1-3-31 381KB Typical Line Valve Chamber for 750 Diameter Concrete Pressure Pipe Detail 2 of 2
1-3-32 713KB Typical Line Valve Chamber for 900 Diameter Concrete Pressure Pipe Detail 1 of 2
1-3-33 370KB Typical Line Valve Chamber for 900 Diameter Concrete Pressure Pipe Detail 2 of 2
1-3-34 715KB Typical Line Valve Chamber for 1200 Diameter Concrete Pressure Pipe Detail 1 of 2
1-3-35 365KB Typical Line Valve Chamber for 1200 Diameter Concrete Pressure Pipe Detail 2 of 2
1-3-36 715KB Typical Line Valve Chamber for 1500 Diameter Concrete Pressure Pipe Detail 1 of 2
1-3-37 368KB Typical Line Valve Chamber for 1500 Diameter Concrete Pressure Pipe Detail 2 of 2
1-3-38 714KB Typical Line Valve Chamber for 1800 Diameter Concrete Pressure Pipe Detail 1 of 2
1-3-39 368KB Typical Line Valve Chamber for 1800 Diameter Concrete Pressure Pipe Detail 2 of 2
1-3-40 720KB Typical Line Valve Chamber for 2100 Diameter Concrete Pressure Pipe Detail 1 of 2
1-3-41 372KB Typical Line Valve Chamber for 2100 Diameter Concrete Pressure Pipe Detail 2 of 2
1-3-42 713KB Typical Line Valve Chamber for 2400 Diameter Concrete Pressure Pipe Detail 1 of 2
1-3-43 375KB Typical Line Valve Chamber for 2400 Diameter Concrete Pressure Pipe Detail 2 of 2
1-3-44 765KB Typical Double Drain Chamber for Concrete Pressure Pipe 750 Diameter or Greater Detail 1 of 2
1-3-45 476KB Typical Double Drain Chamber for Concrete Pressure Pipe 750 Diameter or Greater Detail 2 of 2

1-4 Meters
1-4-1 141KB 75 Tru-Flo Compound Meter in Building
1-4-2 145KB 75mm Tru-Flo Compound Meter in Chamber
1-4-3 138KB 100mm and 150mm Tru-Flo Compound Meter in Building
1-4-4 140KB 100mm and 150mm Tru-Flo Compound Meter in Chamber
1-4-5 116KB 38mm and 50mm T–10 Meter in Building
1-4-6 141KB 38mm and 50mm T-10 Meter Chamber Installation on D.I. or P.V.C. Watermain
1-4-6A 127KB 38mm and 50mm T-10 Meter Chamber Installation on Copper or Polyethylene Watermain
1-4-7 139KB 16mm X 19mm TO 25mm Meter Installation for 25mm ‘K’ Copper Water Service in Building
1-4-7A 135KB 16mm X 19mm TO 25mm Meter Installation for Polyethylene Water Service in Building
1-4-12 115KB 16 x 19 to 25 Meter in Chamber
1-4-15 148KB 100mm - 250mm Protectus III Meter in Chamber
1-4-16 137KB 100mm - 250mm Protectus III Meter in Building
1-4-17 159KB Meter Chamber for Irrigation System
1-4-17a 197KB Meter Chamber for Irrigation System in Above Grade Utility Box
1-4-18 125KB 50mm Tru-Flo Compound Meter in Building
1-4-19 146KB 50mm Tru-Flo Compound Meter in Chamber
1-4-20 165KB 16 x 19mm to 25mm Meter Installation for Stacked Townhouses

1-5 Bedding & Thrust Restraint
1-5-1 136KB Watermain Bedding
1-5-2 94KB Watermain Support Bridging Disturbed Ground
1-5-2A 156KB Replacement Of C.I. or D.I. Watermain 300mm and Smaller Crossing Utility Trench
1-5-3 68KB Concrete Thrust Collar
1-5-4 142KB Vertical Blocking 5 Degree to 45 Degree Bends
1-5-5 122KB Horizontal Blocking 5 Degree to 45 Degree Bends
1-5-6 145KB Horizontal Blocking 90 Degree Bends and Reducers
1-5-7 146KB Horizontal Blocking Plugs, Caps and Tees
1-5-8 122KB Watermain Insulation Details
1-5-9 509KB Typical Mechanical Thrust Restraint For PVC Pipe

1-6 Fire Protection
1-6-1 360KB Hydrant Setting for D.I. or P.V.C. Pipe
1-6-2 360KB Hydrant Setting for Concrete Pipe
1-6-3 84KB Hydrant Bollards
1-6-4 154KB Fire Line and Domestic Connection

1-7 Watermain Connections
1-7-1 113KB Water Service Connection
1-7-2 96KB Blow-off for 100mm and Larger Watermain
1-7-3 110KB 50mm Off End of Watermain At Cul-de-Sac
1-7-4 65KB Typical 50mm Watermain on Cul-de-Sac
1-7-5 66KB Swabbing Outlet 100mm and Larger
1-7-6 134KB Sampling Station
1-7-6A 133KB Sampling Station North Peel
1-7-7 223KB Temporary Watermain Connection Detail from Watermain
1-7-8 202KB Temporary Watermain Connection Detail from Hydrant
1-7-9 276KB Permanent 300 mm Swabbing Outlet on 400 mm PVC Pipe with Precast Access Chamber
1-7-10 130KB Typical Tracer Wire Installation for Watermain Valves, Hydrants and Tees

1-8 Servicing for Multiple Buildings
1-8-1 95KB Servicing for Industrial Buildings with Easements at the Street Line
1-8-2 69KB Servicing for Townhouse Complex
1-8-3 64KB Servicing for Apartments, Buildings, Schools, Hospitals, Hotels, Motels and Churches
1-8-4 63KB Servicing for Commercial Buildings (Restaurants and Office Buildings) No Hydrant on Private Side
1-8-5 76KB Servicing for Multiple Building Commercial Sites, i.e. Restaurants and Office Buildings One Lot One Owner
1-8-5A 85KB Servicing for Multiple Building Commercial Sites, i.e. Restaurants and Office Buildings One Lot One Owner
1-8-6 63KB Servicing for Industrial Buildings
1-8-7 72KB Servicing for Multiple Building Industrial (Separate or Partial Frontages) One Lot One Owner
1-8-9 108KB Servicing for Multiple Building Industrial Sites (No Frontage)
1-8-10 163KB Reservicing for New Residential Buildings Under Existing Common Servicing Arrangement

 

Revised: Wednesday January 24 2018

www.peelregion.ca

Home | Contact Us | Search | A-Z Topic List
Privacy & Terms of Use | Service Commitment

Smaller Text Larger Text